Vacusart is a ready-to-connect filtration unit for reliable venting of vacuum systems. The permanently hydrophobic PTFE membrane incorporated into this unit reliably retains bacteria, particles and water from gas streams.

Item No.: 
17804----------M
Availability: 
Pieces
3

*Custom/bulk order quotes are provided within 72 hours of request.

Vacusart

Reliable Retention of Bacteria, Particles and Water

Product Information

Vacusart is a ready-to-connect filtration unit for reliable venting of vacuum systems. The permanently hydrophobic PTFE membrane incorporated into this unit reliably retains bacteria, particles and water from gas streams. Vacusart offers the highest possible reliability even at high flow rates and for high moisture content

Applications

Vacusart filter units have been specially designed for reliable venting of vacuum lines and tubing. Vacusart is especially reliable as a water or liquid barrier upsteam of valves or vacuum pumps.

Performance

PTFE is the most hydrophobic material available that is used in gas filtration. Even after undergoing several autoclaving cycles, the PTFE membrane still retains its outstanding hydrophobic properties.

Operating Pressure

3 bar max. (~ 45 psi max.)

Autoclaving Temperature

134°C max.

Technical Specification

Membrane: Reinforced PTFE

Housing: Polypropylene

Membrane Area: 20 cm2

Housing Diameter: 64 mm

Pore Size: 0.45 μm

Connectors: Inlet |Outlet Stepped hose barb 6-12 mm (interior thread fits luer male connector)

Applications

  • Application
    Air/Gas Filtration
  • Application Area
    • Filling and tranfer vessels
    • Fermentation carboys
    • Cell culture chambers
    • CO₂ incubators (6 to 120 liters)
    • Holding and storage tanks
    • Autoclave venting
    • Small bioreactors
  • Industry
    Pharma / Biotech / F&B

Biological Information

  • Bacterial Retention
    Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology

Compliance Information

  • Bacterial Endotoxins
    < 0.25 EU/mL as determined by the LAL test
  • Biocompatibility (USP Class VI)
    USP<88>
  • Biological Reactivity
    All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
  • Extractables
    The total amount of extractables is well below the limits established by the current USP unter "Sterile Water for Injection".

Connections (Physical)

  • Connector Inlet
    Hose Barb 6–12 mm Stepped
  • Connector Outlet
    Hose Barb 6–12 mm Stepped

Dimensions

  • Filter Diameter
    64 mm | 2,5”
  • Filter Size
    20 cm² / 3 in²
  • Filtration Area
    20 cm² / 3 in²

General Specifications

  • Capsule/Cartridge Format
    Midisart®
  • Filter Format
    Capsules
  • Minimum Required Bubble Point
    For 0.2 µm min. Bubble Point > 1100 mbar | 15.95 psi, for 0.45 µm min. Bubble Point > 900 mbar | 13.05 psi , wetting agent: IPA | Water (60 | 40)

Materials of Construction

  • Filter Material
    Polytetrafluorethylene (PTFE)
  • Membrane Material
    Polytetrafluorethylene (PTFE)

Operating Conditions

  • Maximum Differential Pressure
    3 bar
  • Maximum Operating Pressure
    3 bar | 45 psi

Physicochemical Information

  • Gamma Stable
    No
  • Non-Fiber Releasing
    This filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
  • Pore Size
    0.45 µm
  • Pore Size Final-filter
    0.45 µm

Product Information

  • Brand
    Vacusart
  • Pack Size
    3
  • Packaging
    Non-sterile, bulk packed
  • Type
    Air filter

Sterility/Purity

  • Delivery Condition
    Non sterile - Autoclavable
  • Sterilization Method
    Autoclavable
  • Sterilizing Grade
    Yes

Usage Protocols

  • Sterilization Procedures
    Max. Temperature 134 °C, max. Autoclaving 20 Cycles