Sartopore® Air Midisart®
The Sartopore® Air Midisart® with its revolutionary hydrophobic 0.2 µm PES membrane completely addresses the rigorous demands of small-scale, single-use, venting applications. Sartopore® Air Midisart® ensures sterilizing-grade venting performance in either direction. Sartopore® Air Midisart® delivers a high level of performance and process security.
- Price (USD):
- $1,680.00
- Item No.:
- 17805--------AIN
- Pieces
- 100
*Custom/bulk order quotes are provided within 72 hours of request.
Choose your Midisart®
Sartopore® Air Midisart®
For critical applications. Perfect for single-use assemblies.
- Hydrophobic PES membrane
- Gamma-irradiatable
- Autoclaving (max. 3 cycles)
- Liquid bacteria challenge test (bi-directionally)
- 100% integrity tested
- Clear laser labeling (no ink used)
- No fleeces used
- Superior flow rates
Critical Application Validation Package:
- Aerosol bacteria challenge test
- Aerosol phage challenge test
- Aerosol particle challenge test
- Particle release specification
Applications:
While Sartopore® Air Midisart® are designed for any kind of (critical) application, Midisart® 2000 cannot be gamma-irradiated (what is required for most single-use applications)
- Filling and transfer vessels
- Holding and storage tanks for sterile media
- Autoclaves
- Carboys
- Solvent filtration
- Mixers
- Small (single-use) fermenters
Sartopore® Air recommended:
- Single-use assemblies
- Disposable bags/bottles
- Tubing systems
- Cell culture chambers
- Fill & Finish applications
Applications
-
ApplicationAir/Gas Filtration
-
Application Area
-
Single-use bioreactors (Sparge | Overlay filter assemblies | Exhaust filter assemblies)
-
Single-use mixing and storage bag vents
-
Single-use liquid filter assemblies requiring PUPSIT (Post Sterilization Pre-Use Integrity Testing)
- Fill-finish
-
Single-use bioreactors (Sparge | Overlay filter assemblies | Exhaust filter assemblies)
-
IndustryPharma / Biotech
Biological Information
-
Bacterial RetentionQuantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Compliance Information
-
Bacterial Endotoxins< 0.25 EU/mL as determined by the LAL test
-
Biocompatibility (USP Class VI)USP<88>
-
Biological ReactivityAll materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
-
ExtractablesThe total amount of extractables is well below the limits established by the current USP unter "Sterile Water for Injection".
Connections (Physical)
-
Connector InletHose Barb 6–12 mm Stepped
-
Connector OutletHose Barb 6–12 mm Stepped
Dimensions
-
Filter Size20 cm² / 3 in²
-
Filtration Area20 cm² / 3 in²
General Specifications
-
Capsule/Cartridge FormatMidisart®
-
Filter FormatCapsules
-
Minimum Required Bubble Point> 950 mbar | 13.8 psi
Materials of Construction
-
Filter MaterialSingle-layer polyethersulfone (PES) membrane
-
Material o-ring | sealSilicone
-
Membrane MaterialPolyethersulfone, Hydrophobic (PES)
Operating Conditions
-
Maximum Differential Pressure2 bar
-
Maximum Operating Pressure2 bar (29 psi)
Physicochemical Information
-
Gamma StableYes
-
Non-Fiber ReleasingThis filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
-
Pore Size0.2 µm
-
Pore Size Final-filter0.2 µm
Product Information
-
BrandSartopore® Air
-
Pack Size100
-
PackagingNon-sterile, bulk packed
-
TypeAir filter
Sterility/Purity
-
Delivery ConditionNon sterile - Gamma irradiatable
-
Sterilization MethodAutoclavable & Gamma Irradiatable
-
Sterilizing GradeYes
Usage Protocols
-
Sterilization Procedures
-
Gamma irradiation with max. 50 kGy.
- Autoclaving: max. 134°C temperature for 30 min. (max. 20 cycles)
-
Gamma irradiation with max. 50 kGy.