Aerosart® Cartridge 0.2 µm 30"
Aerosart® is a high flow rate, low differential pressure, hydrophobic membrane filter. The unique single layer filter construction also reduces Blow-Down-time. Both the high flow rate and the short Blow-Down-time lowers the energy cost of air supply operations.
- Price (USD):
- $5,690.00
- Item No.:
- 5152507T3---E--C
*Custom/bulk order quotes are provided within 72 hours of request.
Choose your Aerosart®
Product Information
Aerosart® high performance air filter cartridges can significantly reduce operating costs.
Applications
- Large-scale fermentation inlet and exhaust gas filtration
- Storage tank venting
- Filling equipment venting
- Any dry gas filtration
Microbiological Testing
They have been tested and passed:
- Aerosol bacterial and viral challenge tests. Tests were conducted using MS-2 coliphage (NCIMB 10108) and bacillus subtils var. niger spores (NCTC 10073) at a challenge level of greater than 2.5 × 10⁷ under worst case conditions of greater than 90% relative humidity. No MS-2 coliphage or B. subtilis spores were detected on the downstream side of the Aerosart® filter cartridges.
- Each membrane lot, liquid bacterial challenge test with the retention of ≥ 10⁷ Brevundimonas diminuta/cm² according to current ASTM F-838 guidelines.
- 100% integrity tested before to be released.
Performance
The unique single layer pleated filter construction of the highly hydrophobic PTFE membrane provides low differential pressures, excellent flow rates and the fastest blow down times of any gas service filter.
Long Service Life Time
The mechanical and thermal stresses experienced during steam in place sterilization pose the highest risk to any filter cartridge. In many cases, Aerosart® filter cartridges will be used for more the 120 steaming cycles. Tests have shown Aerosart® cartridges to pass integrity tests with greater than 150 steaming cycles.
Traceability
Clear labelling with lot number and individual unit number.All information lazer marked on each cartridge.
Applications
-
ApplicationAir/Gas Filtration
-
Application Area
-
Large scale fermentation inlet and exhaust gas filtration
-
Storage tank venting
-
Filling equipment venting
- Any dry gas filtration
-
Large scale fermentation inlet and exhaust gas filtration
-
IndustryPharma / Biotech / F&B
Biological Information
-
Bacterial RetentionQuantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Compliance Information
-
Bacterial Endotoxins< 0.25 EU/mL as determined by the LAL test
-
Biocompatibility (USP Class VI)USP<88>
-
Biological ReactivityAll materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Dimensions
-
Filter Size30"(2.25 m² / 24.2 ft²)
-
Filtration Area2.25 m² | 24.2 ft²
General Specifications
-
Capsule/Cartridge FormatCartridges
-
Filter FormatCartridges
-
Maximum Allowable Back Pressure
-
3 bar | 43.5 psi at 20 °C
- 0.5 bar | 7 psi at 134 °C
-
3 bar | 43.5 psi at 20 °C
-
Minimum Required Bubble Point1.0 bar | 14.5 psi
Materials of Construction
-
Filter MaterialPolytetrafluorethylene (PTFE)
-
Material o-ring | sealEPDM
-
Membrane MaterialPolytetrafluorethylene (PTFE)
-
Support FleecePolypropylene (PP)
Operating Conditions
-
Maximum Differential Pressure5 bar
-
Maximum Operating Pressure5 bar | 72.5 psi at 20 °C0.5 bar | 7 psi at 134 °C
Physicochemical Information
-
Gamma StableNo
-
Non-Fiber ReleasingThis filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
-
Pore Size0.2 µm
-
Pore Size Final-filter0.2 µm
Product Information
-
BrandAerosart®
-
Pack Size6
-
TypeAir filter
Sterility/Purity
-
Delivery ConditionNon sterile - Autoclavable | Steamable
-
Sterilization MethodAutoclavable & In-Line Steam Sterilizable
-
Sterilizing GradeYes
Usage Protocols
-
Sterilization Procedures
-
Autoclaving : 134 °C, 2 bar | 29 psi, 30 min, sterilization cycles: min. 25
- In line Steam sterilization: 134 °C, 20 min. at max differential pressure of 0.5 bar | 7.25 psi, sterilization cycles: max. 150
-
Autoclaving : 134 °C, 2 bar | 29 psi, 30 min, sterilization cycles: min. 25